Metal roofing
Architectural shingles
Tile roofing
GAF
Owens Corning
Flat & low-slopeFree roof inspection with deck photos before we talk money - GAF and Owens Corning certified installation
Boral Ridge Vent Installation: The Los Angeles Owner’s Guide
If your Boral clay or composite tile roof has a ridge vent that’s cracked, lifting, or letting water in, we stock Boral-compatible ridge vent components and install them across Los Angeles for $380 to $720 on most single-story homes, with most jobs finished the same day we arrive. Ridge vent failure rarely announces itself with a bang – it shows up as granules in the gutter, a faint water stain on the ceiling near the peak, or a ridge cap that’s shifted a quarter inch out of line after a Santa Ana wind. The part sits at the highest stress point of the roof: maximum sun exposure, maximum wind shear, and maximum heat, which means it ages faster than any other component up there. Grant Whitlock and our Mercer Roofing crew have replaced hundreds of these across the LA basin, and the pattern is consistent – the vent material itself usually outlasts the fasteners and sealant holding it in place.
Which Boral Models This Applies To
Boral roof tile systems worth protecting with a proper ridge vent installation break into three families: Boral Concrete Roof Tile, Boral Terracotta Clay Tile, and Boral Steel Roofing (the Boralsteel line). Each uses a different ridge vent profile, so the first thing we do on any job is confirm what you have. Concrete tile ridges take a low-profile vent that follows the tile’s rounded crown, usually a 12-inch repeat on the vent sections. Terracotta is thinner and flatter, so the vent has to sit closer to the deck and the flashing changes. Boralsteel uses a ventilated metal ridge cap that integrates with the panel ribs – it looks different from the tile versions and a real gotcha exists: mixing a Boralsteel vent profile onto a tile roof will leave a gap at the eave ends that invites water. We match OEM parts to Boral profiles whenever they’re available in the Los Angeles supply chain, but for some older clay designs that Boral discontinued, we use a proven aftermarket equivalent with a lower profile than the generic “universal” vents. Those universal pieces are the ones we find failed most often on tile roofs, because they don’t follow the tile’s geometry and mortar can’t seat around them properly.
Styles & brands we work with






Signs Your Boral Ridge Vent Installation Is Failing
- Ceiling stains near interior peak walls. Water travels down the roof’s surface tension before it falls, so the entry point is usually the ridge vent flashing, not the shingle field. The stain shows up on the ceiling before the paint peels because the leak is slow.
- Ridge cap tiles sliding out of alignment. The wind load on a Boral ridge vent in Los Angeles foothill zones – Tujunga, Sunland, Porter Ranch – is enough to walk the caps sideways once the fasteners lose bite. You’ll see a zigzag silhouette against the sky instead of a clean line.
- Tar paper or underlayment visible at the ridge. When the vent separates from the decking, the underlayment gets exposed to direct sun. It dries, cracks, and fails within one Los Angeles summer. You can spot this from the ground with binoculars.
- Higher attic temperatures in August. Ridge vents move the hot air that climbs to the peak. When they clog or collapse, the attic runs 20 to 30 degrees hotter. You’ll notice the upstairs rooms won’t hold temperature even with the AC running.
- Birds or bees using the ridge as an entry. A small gap at the vent end opens a hole all the way into your attic. Starlings in Los Angeles will take that opening in a week. The mud wasp issue shows up in the same spots, and that’s a sign the gap has been there for a while.
See the difference
Before
After
Before
After
Before
AfterReplacement Cost & What’s Included
Replacing a failed Boral ridge vent installation in Los Angeles typically runs $380 to $720 for vent section replacement with new flashing and fasteners on a standard single-story ranch or Spanish-style home. Two-story hillside homes or roofs with steep pitches in neighborhoods like Mount Washington or Baldwin Hills add access time and safety equipment, pushing the range toward $700 to $950. The old vent gets cut out cleanly, the deck edge inspected for rot, new underlayment is tucked in at the transition, then the new vent is set to match the Boral profile and fastened at every required point. The big variable is coring: if the existing ridge opening was cut too narrow when the house was built – very common on 1990s Los Angeles developments – we have to widen it for the vent to breathe at all. Every job starts with a written line-item price before we touch the roof, and every ridge vent replacement includes our 365-Day Done Right Promise: if the work isn’t right within a year, we come back and make it right at no charge.
DIY or Call Us?
There’s exactly one safe DIY task here: photographing your ridge line from the ground, ideally in the morning light when shadows make shifted caps obvious. Anything past that gets risky fast. Walking a tile roof without proper gear means breaking tiles – Boral concrete tile runs about $4 to $6 per replacement piece, and one misstep can crack a dozen. The ridge is the highest point on the roof, often 18 to 25 feet up on Los Angeles homes, and the vent itself sits directly over the living space where a fall through goes straight down through the deck. If you’re considering opening up an existing vent or replacing seals, that work requires removing ridge cap fasteners and lifting tiles without cracking them, which is where we see the most DIY regret. Our crew brings the right tile sleds, roof anchors, and Boral-specific profile knowledge. Call (213) 521-8272 and we’ll give you a written price before anything gets touched.
FAQs
A properly installed Boral ridge vent in Los Angeles lasts 15 to 22 years, with the vent media itself often failing before the tile or metal components around it. Sun exposure is the main killer: the vent material handles heat well, but the adhesive-backed membrane and neoprene washers on the fasteners break down after continuous 100-degree days. Coastal areas like Playa del Rey get salt air that trims lifespan by roughly a third. Call (213) 521-8272 if you’re not sure how old your vent is – we can usually tell from the ground without walking the roof.
Sometimes the flashing can be resealed and re-fastened, but if the vent membrane itself is cracked or the structural profile has pulled, replacement is the only option that won’t leak again inside a year. We’ll always tell you which one you need before any work starts, and our written estimate covers exactly the parts and labor involved.
Most Boral ridge vent replacements in Los Angeles take four to six hours from setup to cleanup. Two-story or steep-pitch jobs can run a full day. We’ll give you a clear window in the written estimate before you approve the work, and every technician arrives with a photo ID badge and their name sent to you before they show up.
We stock the most common Boral concrete and terracotta ridge vent profiles on our trucks, and our Los Angeles suppliers can pull Boralsteel vents same-day in most cases. We stock parts for GAF, Owens Corning, and CertainTeed roof systems too, so we can match what’s already on your roof. If your vent is a discontinued Boral design, we’ll match it with a proven aftermarket equivalent and show you the difference before you pay a dollar.
A roof should be the last thing on your mind – let’s keep it that way. If your Boral ridge vent is showing any of the warning signs above, call (213) 521-8272 for a free, written estimate. We’ll tell you exactly what’s wrong, exactly what it costs, and exactly who’ll be coming to your door before they ring the bell.
Written by Grant Whitlock, Owner, Mercer Roofing Co at Mercer Roofing Co Los Angeles, serving Los Angeles and nearby areas.